Technical Specification of DR X-ray Machine 500mA

Summary

Only Yes/No/Comply should not be written. . Any deviation must be clearly mentioned. Bidders must submit original catalogue/brochure/technical - Bidders must completely fill the Technical Specification Form corresponding page no.

Auto-generated and may contain errors. Check the original notice before you act on it.

Files

Key details

Organization
Mahashila Rural Municipality
Industry
Local Government
Category
Tender/Bids
Published
Notice date
Fiscal year
FY 2083/84
Source
View on the original website
Text extracted automatically from the notice (may contain errors)

| Bidder’s Offer X-Ray Machine 500 mA Remarks es/No [Page no in | atalogue Manufacturer: Brand: 4 Country of Origin: Note to the Bidders: — Only Yes/No/Comply should not be written. . Any deviation must be clearly mentioned. Bidders must submit original catalogue/brochure/technical - Bidders must completely fill the Technical Specification Form corresponding page no. of catalogue/brochure/technical datasheet. (TSF) in detail wit datasheet with the bid document. Description of Function X-ray unit is required to perform routine X-ray studies in the hospital. Operational Requirements: ——t General purpose X-ray machine 500 mA. System Configuration | | । X-ray machine 500 mA with complete accessories. Technical Specifications cee 4 X-ray Generator: ० Must be digital controlled line frequency generator, output 40 KW or above to give a constant output suitable for radiography. Machine ON/OFF switch. KV range: 40KV to 120KV at 50mA mA range: 500 mA or more. mAs range: 0.5 to 300mAs. Control: Digital Must Display mA, mAs & kVP Simultaneous protection from excess selection of mA, mAs, kVP & Input Voltage must be provided for Electronic Overload. A dual action hand switch with retractable cord must be provided for radiation protection of operator. i 4.2 | X-ray Tube: ० Rotating anode X-ray tube with dual focal spot (specify focal spot sizes, smaller focal spot size will be preferable). HT Transformer with Full wave rectified Tube head Collimator with auto/manual shut off facility must be provided. Horizontal Bulky Table(HBT): ० Movable Floating table with motorized Bucky and Bucky grid must be provided. The Bucky tray must accept cassettes up to “14x17”. 43 | | _ ११७ REZ Rrra HO Se 8 crate GE बालाके ८: 4.4 | Column Stand: eis 2 Tube stand from floor to ceiling भुई is] 5.1 | Accessories: की प्रदेश, e Lead apron lightweight with 7 101(11655- 0110. e Wall mounted Chest Stand operate the equipment, including all standard tools and cleaning and lubrication materials, to be included in the offer. Bidders must specify the quantity of every item included in their offer (including items not specified above). 5.2 | All standard accessories, consumables and parts required to a | Operating Environment The system offered shall be designed to operate normally under the conditions of the purchaser's country. The conditions include Power Supply, Climate, Temperature, Humidity, etc. Power supply: 220 or 440 VACS, 50Hz fitted with appropriate plug. The power cable must be at least 3 meter in length, _| Standards and Safety Requirements Must submit ISO13485 for Medical Devices CE, BIS/AERB or USFDA approved Certificate. | User Training Must provide user training (including how to use and maintain the equipment). Warran Comprehensive warranty for 2 years after acceptance. Maintenance Service During Warranty Period During the warranty period supplier must ensure preventive maintenance and corrective/breakdown Installation and Commissioning maintenance whenever required. The bidder must arrange for the equipment to be installed and commissioned by certified or qualified personnel; any prerequisites for installation to be communicated to the urchaser in advance, in detail. Documentation छक User (Operating) manual in English. 12.2 | Service (Technical / Maintenance) manual in English. 12.3 | Must Submit Manufacture Authorization Letter to Bidder provided by Authorized Importer of Nepal, Manufacturer Authorization to Authorized Importer must be Included in this case. es/No |Page no in [Remarks atalogue a । | rand: a | | Model डा सारा a ote to the Bidders: 1. Bidders must completely fill the Technical Specification Form (TSF) in detail with corresponding «पि. : Bidder’s Compliance Sheet a i 2073 _ |__| B a (es) “I (es) page no. of catalogue/brochure/technical datasheet. 2. Only Yes/No/Comply should not be written. 3. Any deviation must be clearly mentioned. it [| Digital Flat Panel Detector हु 1.1 Description of functions: The Flat Panel Detector directs digital radiography unit (portable type) for general purpose radiology any of the X-ray available in the hospital. 1 Flat Panel Detector with workstation should be provided. It shall be suitable for adult and pediatric patients in general radiography 2 | System Configuration a Imaging Workstation:01 Technical Specification Flat Panel Detector System 3.1 The Flat Panel should be a Retrofit Solution and capable to work with any of the X-Ray available in Department. The most advanced CSI Direct-deposition technology ensures excellence of image quality at low X-ray dose and improves operation safety. Portable approx. 14x17 inches size detector or more 3. The detector should be light weight (less than 3.5 Kgs) including battery. वै The Pixel pitch should be equal to or less than 140 microns. 9 Image Matrix size: 3052 pixels x 2500 pixels or better. Image acquisition time should be less than 2.5 sec. -11 | Should have a minimum image depth of 16 bits or more. 4. Bidders must submit original catalogue/brochure/technical datasheet with the bid document. examinations. It should be a retrofit solution and capable to work with Z examination. |__| Medical X-ray Film Printer: Double tray (film based):01 irect Deposit Cesium Iodide (CSI/GOS scintillator. 3.4 | Should incorporate Automatic Exposure Detection Technology. 8 Should have a spatial resolution: 3.4 LP/mm (lines per millimeter) or better. -12 | Data communication should be wireless and wired connection. Ww (es) [न्यु Ww oe cD, « 0६ १९७९ Mahasita WS an AEs 00060100 gs° २ ow ६ हुक Balako™ wo Gandaki by ७0” The Detector should have Detachable [7 Pobyaner Technology battery or Lithium Polymer battery arta, shiguidbe provided with one extra battery of >4000mAh with batféiy, hagkup Sf minimum 6 Hours or more along with battery charger having,g Thgstime not more |) than 2.5hrs. Candarg prov (३1 न The Battery Charger should have facility to charge single / double battery at a time. 3.15_| The detector connectivity should be both wireless and wired. a ee ee Bs fT | 1 or more, a es Workstation: Should be supplied with the following configuration: ० Branded CPU — Intel i5 or Latest model processor, * RAM - 8GB, SSD — 500GB, * OS Window 10, 64 bit or Latest * Display: At least 19” size Full HD LED Monitor 3.19 | Image Manipulation/Post processing Software: * Image post-processing, such as image transformation, including inversion, flip vertically/horizontally, rotation, etc. * Multi patient viewing and printing. ० Image Magnification ० Distance measurement and Angle ० Exporting images in JPEG and DICOM 14 E * Cropping and masking of images (standard software) The offered model must be manufactured in the year 2025. Bidder | | must mention the year of manufacture. -21 | The system should be supplied with Al-based software for automated analysis of Chest X-ray images, fully integrated with the Digital Radiography system and workstation. 3.22 | The AI software shall support Chest X-ray interpretation for the following target abnormalities: Infectious Diseases: Tuberculosis detection with accuracy >90% Lung Abnormalities: Atelectasis, Lung opacity (Consolidation / Infiltration), Pleural effusion, Pulmonary nodule / mass, Pneumothorax with overall accuracy >90%) Cardiovascular Abnormalities: Cardiothoracic ratio calculation, Cardiomegaly detection with accuracy >90%) Or better. -23 | The bidder shall provide AI software name, version and perpetual license. .24 | The AI solution shall be CE approved/marked medical device software. Approval certificates should be submitted. |] ।] | w (es) (vs) Medical X-ray Film Printer | | | a : । |_| कफपणठ्ग ररर] a ।: | 1 | पक] B Double Tray Medical Dry Film Printer should be provided. A Printer should have dry thermal/Laser imager technology. 0.0 | ee: (es) त ny Aice of the®, Balakots ge Ganaaki 7112

Like

0

Views

0

Comments

0

Share

0

Save

Report